20.2 Series operation

20.2 Series operation

Up to three FPS1000 with the same output voltage rating can be connected in series to increase the output voltage or to create a bipolar voltage source. It is recommended to connect diodes in parallel with each output to prevent reverse voltage in case of failure in one of the power supplies.

Each diode should be rated to at least the power supply rated output voltage and output current. Refer to Fig 20-3 for a typical series connection of power supplies.

CAUTION

Series operation is not applicable for units with I2C bus option.

 

FPS-T1U

 

 

+S

 

 

 

 

 

 

 

+V

(*)

 

FPS-1000 Module A

-V

 

 

 

 

 

 

 

 

-S

 

 

FPS-1000 Module B

+S

 

 

+V

 

 

 

 

 

 

 

(*)

 

 

 

 

 

 

-V

 

 

 

 

 

 

 

 

 

 

 

 

 

-S

 

 

FPS-1000 Module C

+S

 

 

ON/

 

 

 

ON/

+V

(*)

 

 

ON/

 

-V

 

 

 

 

 

OFF_1

 

OFF_1

 

OFF_1

 

 

A

 

B

 

C

-S

 

J1(A)-3

J1(A)-12

J2(B)-3

J2(B)-12

J3(C)-3

J3(C)-12

 

 

Fig 20-3 Series operation

Fig 20-3 Series operation +S

Manual background+V

LOAD

Manual background -V

Manual background -S

(*) Diodes are user supplied