H
Original exit/reverse motor and read motor stop.
After a certain period of time, original exit/reverse motor reverses, read motor starts, reverse roller aligns original, and then system reboots.
Original intermediate | NO |
|
transport sensor ON? |
|
|
YES |
|
|
| A certain period | NO |
| of time passed? |
|
| YES |
|
| Jam |
|
Original exit/reverse | NO |
|
|
| |
sensor OFF? |
|
|
YES |
|
|
| A certain period | NO |
| of time passed? |
|
NO | Transport for |
| YES |
| |||
a certain amount of |
| ||
| distance completed? |
|
|
Jam
YES
Original exit/reverse motor and read motor stop.
Gate solenoid OFF
END
June 2005 © TOSHIBA TEC |
3 |
3 - 15