H

Original exit/reverse motor and read motor stop.

After a certain period of time, original exit/reverse motor reverses, read motor starts, reverse roller aligns original, and then system reboots.

Original intermediate

NO

 

transport sensor ON?

 

 

YES

 

 

 

A certain period

NO

 

of time passed?

 

 

YES

 

 

Jam

 

Original exit/reverse

NO

 

 

 

sensor OFF?

 

 

YES

 

 

 

A certain period

NO

 

of time passed?

 

NO

Transport for

 

YES

 

a certain amount of

 

 

distance completed?

 

 

Jam

YES

Original exit/reverse motor and read motor stop.

Gate solenoid OFF

END

June 2005 © TOSHIBA TEC

MR-3018 DESCRIPTION OF OPERATIONS

3

3 - 15

Page 29
Image 29
Toshiba MR-3018 service manual End