G

Scanning start signal sent (level: High)

Exposure and scanning start.

 

Original

exit/reverse

NO

 

 

sensor

ON?

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

A certain period

NO

 

 

 

 

of time passed?

 

 

Original exit/reverse

 

 

 

 

 

 

motor rotates.

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

Jam

 

NO

 

 

 

 

 

Read sensor OFF?

 

 

 

 

YES

NO

A certain period

 

of time passed?

YES

Scanning start signal sent (level: Low)

Scanning completed.

Original exit/reverse

NO

sensor OFF?

 

 

 

 

YES

NO

Transport for

a certain amount of

 

 

distance completed?

A certain period

NO

 

of time passed?

 

 

YES

 

 

 

 

 

 

Jam

YES

H

MR-3018 DESCRIPTION OF OPERATIONS

June 2005 © TOSHIBA TEC

3 - 14

Page 28
Image 28
Toshiba MR-3018 service manual Exposure and scanning start Original