[F] Original exit/reverse motor (M3)

(1)

Take off the original feed motor drive section.

 

(

P.4-21 "[E] Original feed motor drive sec-

 

tion")

(2)

Disconnect 1 connector from the RADF con-

 

trol PC board.

 

 

Fig.4-63

(3) Remove 2 screws, and then take off the orig-

Original exit/reverse motor

inal exit/reverse motor with its bracket.

 

4

(4)Remove 2 screws, and then take off the orig- inal exit/reverse motor by sliding it from the bracket.

Fig.4-64

Bracket

Original exit/reverse motor

Fig.4-65

June 2005 © TOSHIBA TEC

MR-3018 DISASSEMBLY AND ASSEMBLY

4 - 23

Page 57
Image 57
Toshiba MR-3018 service manual Original exit/reverse motor M3