5.Adjustment
5.1Adjustment of Position
Perform this adjustment when the RADF is not installed in the correct position.
Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of the RADF. (See the Service Handbook of the applicable equipment.)
[A] Checking
(1) Open the RADF and install 2 positioning pins (the positioning pins are installed to the back side of the hinge which is on the left side of the RADF).
(2) Remove the platen sheet. |