5.Adjustment

5.1Adjustment of Position

Perform this adjustment when the RADF is not installed in the correct position.

Note:

Check if the image adjustment for the equipment is performed properly before this adjustment of the RADF. (See the Service Handbook of the applicable equipment.)

[A] Checking

(1) Open the RADF and install 2 positioning pins (the positioning pins are installed to the back side of the hinge which is on the left side of the RADF).

Fig.5-1

(2) Remove the platen sheet.

Fig.5-2

5

June 2005 © TOSHIBA TEC

MR-3018 Adjustment

5 - 1

Page 71
Image 71
Toshiba MR-3018 service manual Adjustment of Position