
Replacement Procedures
4.20 LCD unit / FL inverter
CAUTION: When replacing a LCD, it is required that SVP parameter is set. Update with the latest EC/KBC as described in Appendix H “EC/KBC Rewrite Procedures”.
Removing the LCD unit / FL inverter
The following describes the procedure for removing the LCD unit and FL inverter (See Figure
1.Remove Screw rubber cover X4
2.Remove the following screws securing the display mask
M2.5⋅4.0 BIND screw X4
3.Insert your finger between the edge of the display mask and the LCD, and remove the display mask while releasing the latches of display mask.
M2.5x4.0
M 2.5X6.0 BIND screwFigure 4-31 Removing the display mask
Satellite P100 Maintenance Manual |