Replacement Procedures

4.20 LCD unit / FL inverter

CAUTION: When replacing a LCD, it is required that SVP parameter is set. Update with the latest EC/KBC as described in Appendix H “EC/KBC Rewrite Procedures”.

Removing the LCD unit / FL inverter

The following describes the procedure for removing the LCD unit and FL inverter (See Figure 4-31 to 4-34).

1.Remove Screw rubber cover X4

2.Remove the following screws securing the display mask

M2.5⋅4.0 BIND screw X4

3.Insert your finger between the edge of the display mask and the LCD, and remove the display mask while releasing the latches of display mask.

M2.5x4.0

M 2.5X6.0 BIND screwFigure 4-31 Removing the display mask

4-52

Satellite P100 Maintenance Manual (960-Q02)

Page 229
Image 229
Toshiba satellite p100 Removing the LCD unit / FL inverter, 5X6.0 Bind screwFigure 4-31 Removing the display mask