Test Program for Field.

3.4System Test

To execute the System Test select 01 from the Diagnostic Test Menu, press Enter and follow the directions on the screen. The System Test contains two subtests. Move the highlight bar to the subtest you want to execute and press Enter.

Subtest 01 FAN ON/OFF Checking

Select 1,2,3 to control FAN on/off , 1=Fan on , 2=Fan off , 3=Exit .

 

[BD1FAN.EXE] Program Version : 1.0

 

1: Fan On 2: Fan Off 3: Exit

 

 

 

Fan1 Status On Fan1RPM : 5000

or

Fan1 Status OFF Fan1RPM : 0

 

Fan2 Status On Fan2RPM : 4000

or

Fan2 Status OFF Fan2RPM : 0

Subtest 02

Battery Test

 

 

This will display battery information for check , press [ESC] to exit .

voltage

: 12522 mV

Remaining capacity alarm

: 400 mAh

temperature

: 24.4 ‘C

Remaining time alarm

: 10 min

current

: 1330 mA

Battery mode

: 0

average current

: 1327 mA

AtRate

: 0 mA

relative state of charge

: 93 %

At rate time to full

: 65535 min

absolute state of charge

: 89 %

At rate time to empty

: 65535 min

remaining capacity

: 3546 mAh

At rate O. K.

: FFFF

full charge capacity

: 3800 mAh

Maximun error

: 2 %

run time to empty

: -1 min.

Charging current

: 2800 mA

average time to empty

: -1 min.

Charging voltage

: 12600 mA

average time to full

: 101 min.

Manufacturer name

: SANYO

cycle count

: 10 times

Device name

: NS2P3SZDNVWR

design capacity

: 4000 mAh

Device chemistry

: LION

design voltage

: 11100 mV

Manufacturer data

: 0

specification information : 2.1

Manufacture date

: 9/13/2005

serial no.

: 32009

 

 

STATUS

: INIT

 

 

Press [ESC] KEY to exit

Satellite P100 and Satellite Pro P100 Tests and Diagnostics Manual

11

Page 119
Image 119
Toshiba satellite p100 manual System Test, Ffff