Test Program for Field.
3.18 Log Utilities
This function logs error information generated while a test is in progress and stores the results in RAM (Maximum error log : 500 times). This function can store data on a floppy disk. If the power switch is turned off, the error information will be lost. Error information is displayed in the following order:
1.Error count (CNT)
2.Test name and subtest number (TEST)
3.Pass count (PASS)
4.Error status (STS)
5.FDD/HDD or memory address (ADDR)
6.Write data (WD)
7.Read data (RD)
8.Error Name ( ERROR NAME/DETAILS)
3.18.1 Operations
1.Select 04 and press Enter in the Diagnostics Menu to log error information into RAM or onto a floppy disk. Error information is displayed in the following format:
|
| XXXX ERRORS | PASSCOUNT = XXXX | ||||
CNT | TEST | PASS | STS | ADDR | WD | RD | ERROR NAME/DETAILS |
001 | FDD 02 | 0000 | 180 | 0000001 | 00 | 00 | WRITE PROTECTED |
002 | FDD 01 | 0000 | 120 | 0000001 | 00 | 00 | TIME OUT ERROR |
|
|
|
| Address |
|
|
|
|
|
| Error Status |
|
|
| |
|
| Pass Count |
|
|
|
| |
| Subtest Number |
|
| Read Data | |||
| Test Name |
|
| Write Data | |||
Error Count |
|
|
|
|
| Error Name and Detail |
[[1:Next, 2:Prev, 3:Exit, 4;Clear, 5:FD Log Read, 6:FD Log Write, 7:Log Save]]
Satellite P100 and Satellite Pro P100 Tests and Diagnostics Manual | 57 |