Chapter 1 Hardware Overview

1.6 Power Rails

Table 1-6-1 lists the power rail output specifications of CULV platform.

Name

 

Power supply Yes/No

 

 

 

 

 

Voltage [V]

Power OFF

Power OFF

No Battery

 

 

Suspend mode

Boot mode

 

 

 

 

 

 

 

 

+5VPCU

5

Yes

Yes

No

 

 

 

 

 

+5V

5

No

No

No

 

 

 

 

 

+3VPCU

3.3

Yes

Yes

No

 

 

 

 

 

+3V_S5

3.3

Yes

No

No

 

 

 

 

 

+3VSUS

3.3

Yes

No

No

 

 

 

 

 

+3V

3.3

No

No

No

 

 

 

 

 

+1.8VSUS

1.8

Yes

No

No

 

 

 

 

 

+SMDDR_VTERM

1.8

Yes

No

No

 

 

 

 

 

+SMDDR_VREF

1.8

Yes

No

No

 

 

 

 

 

+1.8V

1.8

No

No

No

 

 

 

 

 

+1.5V

1.5

No

No

No

 

 

 

 

 

+1.2V

1.25

No

No

No

 

 

 

 

 

+1.05v

1.05

No

No

No

 

 

 

 

 

+NB_CORE

1.0~1.2

No

No

No

 

 

 

 

 

VCC_CORE

0.7~1.2

No

No

No

Table 1-6-1 CULV Power supply output rating

Satellite T110 / Satellite Pro T110 /PROTEGE110 Maintenance Manual (960-Q08)

13

Page 28
Image 28
Toshiba T110, ProT1!0 manual Power Rails