Test Program for Field.

with the original data patterns. Addresses are displayed in 64KB increments during the test.

Test Process:

1. Byte Enable Test

One bit write/ 8 bit read” is executed and the new data is compared with the original data.

Test data = CCAA5533H, 80000000H

2.Byte Enable Test

“One bit write/16 bit read” is executed and the new data is compared with the original data.

Test data = CCAA5533H, 80000000H

3.Data bus test

“One bit write/16 bit read” is executed and the new data is compared with the original data.

Test data = 1H, 2H, 4H, 8H, 10H, through 80000000H.

4.Fixed data test

“16 bit write/ 16 bit read” is executed and the new data is compared to the original data.

Test data = FFFFFFFFH, 00000000H, 80018001H

5.Address pattern test

“16 bit write and 16 bit read” of address pattern data is executed and the new data is compared with the original data.

Test data = 0000H, 0004H, 0008H, 000CH,...8000H, 8004H, through

FFECH

Subtest 04 RAM Refresh

This subtest writes a data pattern (CCAA5533H ) in 4KB from 0 to the maximum installed memory, then waits for a memory refresh cycle (16 ms or more), reads the new data, and compares the result with the original data pattern.