Commander Installation Guide

5.4500-41-XX SERIES DESKTOP PANELS

Early desktop panel were DC powered from a mains power supply unit connected via a mini DIN connector on the rear. From 2003 onwards, panels have an internal mains power supply. The only remaining user connection is to the Headset connector on the rear of the desktop.

The following wiring applies to panels marked "Mod State 2" and later. Earlier panels had pins 4 and 6 transposed internally, with corresponding changes to the interconnecting cable. The later wiring allows operation over longer cable runs.

RJ-45 connection to Matrix

 

 

 

 

 

 

 

 

 

 

 

 

 

Headset - 5 Pin XLR Fixed Socket

 

RJ-45

Function

 

 

 

 

Pin

 

 

 

 

 

(Rear panel)

 

1

Panel Data out +

 

Pair

 

 

 

 

 

 

 

 

 

2

Panel Data out -

 

1

 

 

Pin

Function

 

3

Panel Data In +

 

Pair

 

1

Mic IN (Screen)

 

6

Panel Data In -

2

 

 

2

Mic IN

 

5

Panel Audio out +

 

Pair

 

 

3

Headset Gnd

 

4

Panel Audio out -

 

3

 

 

4

Headset Out

 

7

Panel Audio in +

Pair

 

5

Headset Out

 

 

 

4

 

 

 

 

8

Panel Audio in -

 

 

 

 

 

n/c

Cable Screen

 

 

 

 

 

 

Note: As delivered, 500-41 Series Desktop Panels will not operate with T-Edit (early DOS configuration editor) based systems. An internal link must be changed and full details are given in Section 10.1.

Trilogy Communications Limited

Issue 9

Page 37 of 81

Page 37
Image 37