10.CONTROL PANEL CONFIGURATION

10.1500-3X-5X SERIES INTERNAL PANEL SWITCH SETTINGS

Id

DIP Switch Action

DIP

DIP

DIP

DIP

DIP

DIP

DIP

DIP

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

Legacy

5/8

 

 

 

 

 

 

 

 

Emul.

Char

 

 

 

 

 

 

 

 

 

 

0

8 Key or Desktop

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

1

8 Key Expansion

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

16 Key

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

16 Key Expansion

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

4

24 Key

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

24 Key Expansion

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

8

8 REN Expansion

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

12 REN Expansion

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

10

32 Channel Level Control

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

12 Key 1U

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

12

15 Key 1U Expansion

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

10.2500-41 DESKTOP PANEL INTERNAL SETTINGS

A three way connector inside the panel may be fitted with links in any of the three positions labelled H, L or M. These provide the same functionality as the switches accessible from the top edge of the 500-30 series control panel.

Cut Switch Action

H

L

M

No action

X

X

X

Changeover to HSet MIC (default)

X

X

LS cut

X

X

Changeover to HSet MIC and LS cut

X

Panel MIC cut

X

X

Changeover to HSet MIC and MIC cut

X

LS cut and MIC cut

X

Everything

indicates link fitted

 

 

 

X indicates link not fitted

 

 

 

In addition, the 500-41 desktop panel is factory configured to operate with PathFinder systems. To set the panel software to emulate T-Edit systems, solder a shorting link in the position labelled R130. This requires surface mount soldering tools: contact Trilogy for further advice.