Commander Installation Guide

5.7500-42-50 1U, 10 LEVER KEY PANEL WITH LED DISPLAYS. Information about the following legacy panel types is also provided here:

500-44-50 1U, 10 lever key reduced facility control panel without displays.

500-44-51

5.7.1SPECIFICATION

Dimensions

485mm wide x 44.5mm high x 150mm deep

 

(excluding connectors) 200m approx. (including

 

mating connectors)

 

19” x 1RU rack mounting

 

 

Mains Input

90 – 260 V ac, 50-60Hz

 

 

Current Consumption

150mA @ 90V ac, 50mA @ 250V ac.

 

 

5.7.2REAR CONNECOR LAYOUT

5.7.3CONNECTIONS

Expansion out – RJ-45 fixed socket on panel

RJ-45

Function

 

 

 

Pin

 

 

 

 

1

Panel Data in +

 

Pair

 

2

Panel Data in -

 

1

 

3

Panel Data out +

 

Pair

6

Panel Data out -

2

 

5

Panel Audio out +

 

Pair

 

4

Panel Audio out -

 

3

 

7

Panel Audio in +

Pair

8

Panel Audio in -

4

 

 

Cable Screen

 

 

 

Matrix – RJ-45 fixed socket on panel

RJ-45

Function

 

 

 

Pin

 

 

 

 

1

Panel Data out +

 

Pair

 

2

Panel Data out -

 

1

 

3

Panel Data In +

 

Pair

6

Panel Data In -

2

 

5

Panel Audio out +

 

Pair

 

4

Panel Audio out -

 

3

 

7

Panel Audio in +

Pair

8

Panel Audio in -

4

 

 

Cable Screen

 

 

 

Trilogy Communications Limited

Issue 9

Page 43 of 81