Commander Installation Guide

8.5.4500-40-0X SERIES EXPANSION PANELS

Control Panels may be linked together to provide additional facilities at one operating position. Additional level controls (RENs) or switches may be added. Alternatively, two standard panels from the 500-30 series may be linked together and will only utilise a single matrix port.

The following detail refers to expansion panel types:

500-40-00 8 way encoder panel

500-40-01 12 way encoder panel

500-40-02 15 key switch panel

500-40-04 32 way encoder panel An installation specification is given below.

Dimensions

485mm wide x 44.5mm high x 100mm deep

 

(excluding connectors) 150mm deep (maximum

 

including mating connectors)

 

19” x 1RU rack mounting

 

 

Mains Input

90 – 260 V ac, 50-60Hz

 

 

Current Consumption

150mA @ 90V ac, 50mA @ 250V ac.

 

 

8.5.4.1Connector Pin Out

Expansion In - D9 Fixed Socket

Pin

Function

1

Analyse Input

2

Enable Remote Boot

3

Ground

4

Transputer Link Out +

5

Transputer Link In +

6

Error signal Out

7

Reset In

8

Transputer Link Out-

9

Transputer Link In-

Test Port– D9 Fixed Socket

 

 

Pin

Function

1

Analyse Input

2

Enable Remote Boot

3

Ground

4

Transputer Link Out +

5

Transputer Link In +

6

Error signal in

7

Reset Out

8

Transputer Link Out-

9

Transputer Link In-

Expansion Out– D9 Fixed Socket

Pin

Function

1Analyse Input

2Enable Remote Boot

3Ground

4Transputer Link Out +

5Transputer Link In +

6Error signal in

7Reset Out

8Transputer Link Out-

9Transputer Link In-

Trilogy Communications Limited

Issue 9

Page 71 of 81

Page 71
Image 71
Trilogy Touch Technology manual 4 500-40-0X Series Expansion Panels, Connector Pin Out Expansion In D9 Fixed Socket