Commander Installation Guide

5.9500-31-60 STANDARD FACILITY 16 KEY CONTROL PANEL

The 500-31-60 panel provides 16 programmable lever keys in a 2U rack mount chassis. For information on programming the software driven “cut switch” operation, see section 10.3.

5.9.1SPECIFICATION

Dimensions

485mm wide x 88.9mm high x 80mm deep

 

(approx. including PSU and mating connectors).

 

19” x 2RU rack mounting

 

 

Mains Input

90 – 250 V ac, 50-60Hz

Current Consumption

150mA @ 90V, 50mA @ 250V

5.9.2REAR PANEL LAYOUT

Connector types:

Matrix

RJ 45 socket

GPIO

D9 Fixed Socket

Audio I/O

D15 Fixed Socket

Footswitch

D9 Fixed Socket

Matrix – RJ-45 fixed socket on panel

RJ-45

Function

 

 

 

Pin

 

 

 

 

1

Panel Data out +

 

Pair

2

Panel Data out -

1

 

3

Panel Data In +

 

Pair

 

6

Panel Data In -

 

2

 

5

Panel Audio out +

 

Pair

4

Panel Audio out -

3

 

7

Panel Audio in +

 

Pair

 

8

Panel Audio in -

 

4

 

 

Cable Screen

 

 

 

Headset - 5 Pin XLR Fixed Socket (front panel)

Pin

 

Function

1Mic IN (Screen)

2Mic IN

3Headset Gnd

4Headset Out

5Headset Out

Foot Switch - D9 Fixed Socket

Pin

 

Function

1Foot Switch Input

2No Connection

3Chassis Ground

4Reserved

5Reserved

6Ground

7Reserved

8Reserved

9Reserved