Commander Installation Guide

6.2.3CONNECTING THE HARDWARE

The instructions below assume that the PC is currently fitted with a suitable transputer link adaptor card and is in use for the PathFinder application.

Close PathFinder

Identify the download interconnection cable.

¾For desktop computers fitted with the Archipel link adaptor card, this will normally be a grey coloured D37 (PC) to D9 (Commander).

¾Disconnect the cable at both ends and replace with the violet coloured programming lead. Connect only at the computer.

¾For computers fitted with the Sundance SMT104 PCMCIA link adaptor, this will normally be a multi-part cable, with a D25 Male-Female “join”. Break this join.

¾Connect the violet D25-D9 cable instead.

Move the “free” D9 connector to the front of the matrix. This may be connected directly to:-

¾500-01-10 TDM Controller

¾500-02-1x Talkback Controller

¾500-3x-3x and 500-4x Series Control Panels

An additional D9 –Molex adaptor is required to reprogram the 500-08-10 Changeover Card. See section 6.2.4.4.

6.2.4COMPLETING THE REPROGRAM SEQUENCE 6.2.4.1 500-01-10 TDM Controller

Carry out all the steps detailed in Sections 6.2.2 and 6.2.3. Now ensure that everyone is aware that the intercom system is about to go “off air”.

Connect the violet programming lead to the D9 connector on the front of the module. Halt the system by pressing the reset switch on the TDM controller.

On the PC, click the Program button. The progress bar indicates that the Flash RAM is being erased, then reprogrammed. A message box indicates that the procedure is complete.

If the frame is fitted with additional TDM controllers (either >96 ports or fault tolerant), then move the D9 to the next module and repeat the process.

When all modules have been reprogrammed, switch the power off, wait 10 seconds, then turn the power back on. Check that the system is running by observing the LED pattern on the TDM controllers.

6.2.4.2500-02-1x Talkback Controller

Follow the instructions in the preceding section. Always ensure that the correct hardware type is selected in the drop down list box and the appropriate programming code is loaded.

6.2.4.3500-3x-3x Control Panels

Control panels may be re-programmed without disruption to the matrix. Connect the violet programming lead to the rear connector labelled "Test/Debug”. After completing the programming sequence, re-start the panel by removing the mains power for a few seconds. Check that the panel re-initialises correctly by observing the LCD screen, which will display the current software version briefly. For panels without an alphanumeric display, check for correct operation.

Trilogy Communications Limited