Commander Installation Guide

2.5MAINS CONNECTION AND FUSING

2.5.1500-15-30 SERIES POWER SUPPLY

The PSU chassis occupies an additional 2U of rack space below the matrix and is internally wired. The complete assembly therefore occupies 8U for a 96 port system, 14U for a 192 port system etc. The PSU is half rack width allowing two PSU modules to be fitted, thus providing backup operation.

Each power supply is fitted with a D9 socket, which provides a relay contact indicating the PSU status. The table below gives details. Connection should only be made to the pins indicated: any other connections may cause failure of the power supply unit. There is also an auxiliary power connector: details below.

D9 Fixed Plug Pin

Function

1

Relay normally closed

2

Relay normally open

3

Relay common

XLR4 Fixed Socket Pin

Function

1

0V

2

+15V

3

No connection

4

-15V

Note: The Aux power connector is protected by an internal self-resetting thermal fuse. Left and right (main and standby) supplies may be connected in parallel.

The power supplies are switched-mode units and will cope automatically with an input voltage of between 98 and 260 volts AC. This should be wired according to the instructions provided with your mating mains socket using suitable cable. See below for earthing details.

The mains plug has an integral fuse tray fitted with a 20mm glass cartridge slow blow/anti- surge fuse. The fuse rating is marked adjacent to each fuse tray.

2.5.2EARTHING REQUIREMENTS

The Trilogy 500-15-30 units are provided with a single 4mm-earthing stud on the rear panel. Incoming mains earth from the IEC connector is internally bonded to both the chassis and technical 0V to meet safety requirements and performance specifications. The stud allows the addition of an earth strap in rack installations.

Page 16 of 81

Issue 9

Trilogy Communications Limited

Page 16
Image 16