Trilogy Touch Technology 9 Serial Link RS232 / RS422, RS232 configuration, RS422 configuration

Models: 9

1 81
Download 81 pages 24.1 Kb
Page 24
Image 24

Commander Installation Guide

3.4.3SERIAL LINK (RS232 / RS422)

The current version of PC connector plate, which is fitted on the rear right hand side of the Commander Matrix frame, provides either RS232 or RS422 connection capability. The factory default setting is RS232: this may be changed by removing the 4 fixing screws, withdrawing the rear connector assembly and moving the PCB mounted jumper links to the alternate position. Most computers are fitted with D9 fixed sockets for the serial COM port. For older models equipped with a D25, suitable adaptors may be easily obtained.

RS232 configuration.

Commander Sub D9 Fixed Socket - Pin

Function

PC COM Port D9 Fixed Socket

1

DCD

1

2

TX

2

3

RX

3

4

DTR

4

5

0V or GND

5

6

DSR

6

7

CTS

7

8

RTS

8

9

n/c

9

Case

 

 

Note: Pin 1 through to Pin 8 MUST be wired 1:1. CAT 5 cable is suitable for most applications.

RS422 configuration.

Commander Sub D9

 

 

Fixed Socket Pin (+,-)

Function

Notes

4,8

422 in, +,-

Pair 1 (RX)

6,1

422 out, +,-

Pair 2 (TX)

7,2

422 RTS +,-

Pair 3

5,9

422 CTS +,-

Pair 4

3

 

Chassis

Connection to external equipment will depend on the manufacturer and model of RS422 card fitted. The table above only relates to the matrix.

3.4.4ALARMS

These are provided on a 9 way D type fixed socket on the rear of the matrix. The function of the output is software controlled from the 500-08-10 Changeover card. The output is a normally made, solid state relay contact. Maximum current rating is 120mA.

 

Commander

 

 

 

 

 

 

 

 

D9 Fixed Socket - Pin

Function

Notes

 

 

1,6

Right side OK

Pair 1

 

 

2,7

Left side OK

Pair 2

 

 

4,8

C/O Card OK

Pair 3

 

 

5,9

Left side selected

Pair 4

 

 

 

3

 

Chassis

 

 

 

 

 

 

Page 24 of 81

Issue 9

Trilogy Communications Limited

Page 24
Image 24
Trilogy Touch Technology 9 manual Serial Link RS232 / RS422, RS232 configuration, RS422 configuration, Alarms