(Only when the delay function is set to ON) (B10) Delay time setting

D E L A Y – O N

T I M E – 0

Set the delay time.

Setting Range

0 – 40 ms (default: 0), 1 ms steps

Note

Maximum 40 ms total of time for Output channels 1 and 2.

When the T-001T is used, maximum 40 ms total of time for each pair of Output channels 3 and 4, 5 and 6, and 7 and 8.

Delay time can be adjusted to up to 40 ms in total for the amplifier's Output channels 1 and 2, and for the paired output channel when the T-001T is used.

For example, when the delay time for Output channel 1 is set to "30," set that for Output channel 2 to "10" or less. If the delay time for Output channel 2 is set to over "10," that for Output channel 1 is automatically adjusted so that the total delay time for both channels becomes 40.

54