10.7.2. Control input function setting items

Unless otherwise specified, use the Parameter setting knob for each parameter selection.

(E1) Control input function setting

C - I N 0 1 – N O N E

Setting Range

C-IN01 to 12: NONE (default), LOADBANK (Scene memory recall), VOLUP (volume up), VOLDOWN (volume down), CH ON (channel ON), CH MUTE (channel mute), EMG-MUTE (Cut-off by Emergency control), POWER (Power ON/OFF remote control)

ZM-IN01 to 12: NONE (default), LOADBANK, VOLUP, VOLDOWN

Sets the functions to be assigned to the control input terminals or control buttons of the ZM-9001 or ZM-9002.

[When the function is set to LOADBANK]

(E2)

(When the control input function is set to LOADBANK)

C - I N 0 1 – L O A D B A N K

Closing the control input terminal recalls the settings saved in a Scene memory bank number.

Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously set function on it if there is.

(E3) Scene memory bank number selection

C - I N 0 1 – L O A D B A N K 0 1

Select the bank number to recall.

Setting Range

01 – 32 (default: 01)

[When the function is set to VOLUP or VOLDOWN]

(E4)

(When the control input function is set to VOLUP)

C - I N 0 1 – V O L U P

(E5)

(When the control input function is set to VOLDOWN)

C - I N 0 1 – V O L D O W N

Assign the volume-up or volume-down function to the control input.

Closing the control input terminal increases or decreases the volume of the set input or output channel. Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously set function on it if there is.

69

Page 69
Image 69
Vax M-9000 Control input function setting items, E1 Control input function setting N 0 1 N O N E, N 0 1 L O a D B a N K