(C12) ANC monitor switching ON/OFF setting

A N C M O N S E L E C T = O N

If there are 2 or more ANC inputs, set whether or not ANC inputs to be monitored are switched.

Setting Range

OFF (default), ON

(C13) Monitor switching control input terminal setting (When the ANC monitor switching is set to ON)

M O N S E L E C T C I N 0 1

Select the control input terminal to switch the ANC inputs* to be monitored.

Selecting the terminal overwrites the previously set function on it if there is.

Setting Range

CIN01 – 04, CIN01 – 12 when C-001T is used (default: CIN01)

Each time the designated terminal is closed, the ANC inputs to be monitored are switched in numerical order from ANC input 1.

*ANC inputs are the input channels of AN-001T Ambient Noise Sensor Input module. One AN-001T module has 2 input channels. When 2 AN-001T modules are mounted, the AN-001T's inputs in the slot with smaller number correspond to ANC Input channels 1 and 2, and another's inputs in another slot to ANC Input channels 3 and 4.

(C14) Interlock output control setting (When the ANC monitor switching is set to ON)

M O N S E L S Y N C O N

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the control input terminal closure of the set number.

Setting Range

OFF (default), ON

(C15) Monitored ANC input channel selection

(When the ANC monitor switching is set to ON, and the interlock output control to ON)

S E L E C T S Y N C A N C 1

Select the ANC input channel. Each channel for which the monitor function is set to ON can be selected.

Setting Range

ANC 1 – 4 (Only ANC input channels for which the monitor function is ON)

(C16) Interlock output terminal setting

(When the ANC monitor switching is set to ON, and the interlock output control to ON)

S E L E C T S Y N C C O U T 0 1

Set the control output terminal which is closed in synchronization with switching to the monitored ANC input channel.

Assigning the function to this terminal overwrites the previously set function on it if there is.

Setting Range

COUT01 – 04, COUT01 – 12 when C-001T is used (default: COUT01)

59

Page 59
Image 59
Vax M-9000 operating instructions N S E L S Y N C O N