(C4) Control input terminal number selection

C - I N 0 1 N O N E

Setting Range

C-IN01 – 04 (C-IN01 – 12 when C-001T is used), ZM-IN01 – 12* (default: C-IN01)

* Selectable only when the Remote controller type (p. 58-C10)is set to ZM-9001 or ZM-9002.

Set the control input terminal number to be assigned to the control input function.

The screen indications ZM-IN01 – 06 or 01 – 04 correspond to the control buttons of the ZM-9001 or ZM-9002 connected to the 9000 Series amplifier's remote volume control terminal 1 (REMT VOL 1). The indications of ZM-IN with subsequent numbers correspond to ZM-9001's or ZM-9002's control buttons connected to the remote volume control terminal 2 (REMT VOL 2).

To set a terminal number, refer to p. 68 for the flow chart of the control input function setting.

Note: The control input terminal having the PG TRIG (paging trigger) function is represented as "NONE" on the screen.

(C5) Control input terminal function display

C I N 0 1 I N F - N O N E

Displays the function assigned to the control input terminal.

The screen indications represent the following functions:

• NONE:

No function is assigned.

• PG TRIG:

Paging activation

• SCENE:

Scene memory recall

• VOLUP:

Volume up

VOLDOWN: Volume down

• CH ON:

Channel ON

CH MUTE: Channel mute

EMG MUTE: Emergency mute activation (All output channel mute)

POWER: Power ON

(C6) Control input terminal status display (when all are open)

C - I N = _ _ _ _ _ _ _ _ _ _ _ _

(C6) Control input terminal status display (when all are closed)

C - I N = 1 2 3 4 5 6 7 8 9 A B C

Status of all control input terminals can be confirmed on the screen, with the terminal Nos. 1 – 12 arranged in numerical order from left to right.

When closed, the terminal number is indicated by alpha-numerals. Alphabet A represents the terminal number 10, B represents 11, and C represents 12.

An open terminal is indicated by an underscore "_".

(C7) Control output terminal number selection

C - O U T 0 1 N O N E

Setting Range

C-IN01 – 04, C-IN01 – 12 when C-001T is used

Set the control output terminal number to be assigned to the control output function.

To set a terminal number, refer to p. 73 for the flow chart of the control output function setting.

Note: The control output terminal having the function of CH MUTE (Channel mute), EMG MUTE (Emergency mute, or all output channel mute), or PG OUT (Paging activation) is represented as "NONE" on the screen.

57

Page 57
Image 57
Vax M-9000 operating instructions N 0 1 N O N E, N = 1 2 3 4 5 6 7 8 9 a B C