10.8.2. Control output function setting items

Unless otherwise specified, use the Parameter setting knob for each parameter selection.

(F1) Control output function setting

C - O U T 0 1 N O N E

Setting Range

NONE (default), POWER (Power ON/OFF remote control), SCENE (Scene memory recall), CH ON (channel ON)

Select the function assigned to the control output terminal.

[When the function is set to POWER]

(F2)

(When the control output function is set to POWER)

C - O U T 0 1 P O W E R

Provides a Level output when the power is turned on.

Assigning a function to this terminal overwrites the previously set function on it if there is.

[When the function is set to SCENE]

(F3)

(When the control output function is set to SCENE)

C - O U T 0 1 S C E N E

Provides a Level output when a Scene memory is recalled.

Assigning a function to this terminal overwrites the previously set function on it if there is.

(F4) Scene memory bank number selection

C - O U T 0 1 – S C E N E

0 1

Select the Scene memory bank number that causes the selected control output terminal to provide a Level output when the Scene memory is recalled.

Assigning a function to this terminal overwrites the previously set function on it if there is.

[When the function is set to CH ON]

(F5)

(When the control output function is set to CH ON)

C - O U T 0 1 C H O N

Provides a Level output when the input or output channel becomes on.

Assigning a function to this terminal overwrites the previously set function on it if there is.