(E6)

Input/Output channel number selection (VOLUP)

C - I N 0 1 – V O L U P

I N 1

(E7)

Input/Output channel number selection (VOLDOWN)

C - I N 0 1 – V O L D O W I N 1

Using the Input channel or Output channel selection key, select the channel number for which you want to change the volume.

One control input can change one input or output channel volume.

You can change the sound volume for a channel even with the channel off, but not adjust it while monitoring the sound.

Setting Range

IN1 – 8, OUT1 – 2, Max. OUT8 when T-001Ts are used (default: IN1)

(E8) Volume increasing level setting

C - I N 0 1 – V O L U P

0.5

Set the volume level (dB) to increase or decrease.

(E9) Volume decreasing level setting

C - I N 0 1 – V O L D O W N 0.5

Setting Range

0.5 – 10.0 dB (default: 0.5)

[When the function is set to CH ON]

(E10)

(When the control input function is set to CH ON)

C - I N 0 1 – C H O N

Assign the function to turn on the designated input or output channel to the control input terminal. Closing the set control input terminal turns on the designated input or output channel.

Assigning a function to this terminal overwrites the previously set function on it if there is.

(E11) Input/Output channel number selection

C - I N 0 1 – C H O N

I N 1

Select with the input or output channel selection key the input or output channel to turn ON. One control input can turn on one input or output channel.

Setting Range

IN1 – 8, OUT1 – 2, Max. OUT8 when T-001Ts are used (default: IN1)

[When the function is set to CHMUTE]

(E12)

(When the control input function is set to CHMUTE)

C - I N 0 1 – C H M U T E

Assign the function that mutes the input or output channel to the control input. Closing the control input terminal mutes the set channel.

Assigning a function to this terminal overwrites the previously set function on it if there is.

70