71
(E13) Input/Output channel number selection
C- IN01 CH
M
UTE IN1
(E14) Interlock output control setting
C- IN01 SYNC
O
FF
Using the Input channel or Output channel selection key, select the channel number to be muted.
One control input can mute one input or output channel.
IN1 8, OUT1 2, Max. OUT8 when T-001Ts are used (default: IN1)
Setting Range
Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.
ON, OFF (default)
Setting Range
C- IN01 C-
O
UT01
(When the interlock output control is set to ON)
(E15) Interlock output terminal setting
This screen is displayed only when the interlock output control is set to ON.
Set the control output terminal which is closed in synchronization with the control input of the set number.
Assigning a function to this terminal overwrites the previously set function on it if there is.
C-OUT01 04, C-OUT01 12 when C-001T is used (default: C-OUT01)
Note: When the interlock output control ON/OFF setting is ON.
Setting Range
[When the function is set to EMG-MUTE]
(E16)
(When the control input function is set to EMG-MUTE)
C- IN01 E
MG
-
M
UTE
Assign the function that simultaneously mutes all output channels to the control input. Closing the control input
terminal mutes all output channels.
This function is used to mute the output provided from the unit during emergency broadcast operation.
Assigning a function to this terminal overwrites the previously set function on it if there is.
(E17) Interlock output control setting
C- IN01 SYNC
O
FF
Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.
ON, OFF (default)
Setting Range