(E13) Input/Output channel number selection

C - I N 0 1 – C H M U T E I N 1

Using the Input channel or Output channel selection key, select the channel number to be muted. One control input can mute one input or output channel.

Setting Range

IN1 – 8, OUT1 – 2, Max. OUT8 when T-001Ts are used (default: IN1)

(E14) Interlock output control setting

C - I N 0 1 – S Y N C

O F F

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the control input terminal closure of the set number.

Setting Range

ON, OFF (default)

(When the interlock output control is set to ON) (E15) Interlock output terminal setting

C - I N 0 1 – C - O U T 0 1

This screen is displayed only when the interlock output control is set to ON.

Set the control output terminal which is closed in synchronization with the control input of the set number. Assigning a function to this terminal overwrites the previously set function on it if there is.

Setting Range

C-OUT01 – 04, C-OUT01 – 12 when C-001T is used (default: C-OUT01)

Note: When the interlock output control ON/OFF setting is ON.

[When the function is set to EMG-MUTE]

(E16)

(When the control input function is set to EMG-MUTE)

C - I N 0 1 – E M G - M U T E

Assign the function that simultaneously mutes all output channels to the control input. Closing the control input terminal mutes all output channels.

This function is used to mute the output provided from the unit during emergency broadcast operation. Assigning a function to this terminal overwrites the previously set function on it if there is.

(E17) Interlock output control setting

C - I N 0 1 – S Y N C

O F F

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the control input terminal closure of the set number.

Setting Range

ON, OFF (default)

71

Page 71
Image 71
Vax M-9000 E14 Interlock output control setting, N 0 1 S Y N C, N 0 1 E M G M U T E, E17 Interlock output control setting