(A11) Gate ON/OFF setting (when the D-001T is used)

I N 1 – G A T E – O N

Set the gate function (p. 26) to ON or OFF.

Setting Range

ON, OFF (default)

ON: Activates the gate function.

OFF: The gate function does not work.

(When the D-001T is used and the gate function is ON) (A12) Gate threshold level setting

G A T E T H R E S H O L D – 3 0

Set the input sensitivity to activate the gate function (p. 26).

Setting Range

–40 to –5 dB (default: –30 dB), 5 dB steps

(A13) Pre-paging tone ON/OFF setting (when the ZP-001T is used)

P R E P A G E T O N E – O F F

Set whether or not to sound a one-tone chime before paging.

Setting Range

ON, OFF (default)

When set to OFF, the tone does not sound at the paging telephone, either.

(A14) Operation mode setting (when the ZP-001T is used)

M O D E = P A G I N G P O R T

Select the method of activating paging.

Setting Range PAGING PORT (default), RING SIGNAL

PAGING PORT: Paging is operated if a start signal (no-voltage make signal) is received from the paging port when the connection between the unit and PABX is established.

RING SIGNAL: Paging is operated if an IR signal is received when the connection between the unit and PABX is established. The ZP-001T module functions as a telephone.

(A15) ANC operation ON/OFF setting (when the AN-001T is used and ANC operation is set to ACTIVE)

A N C A C T I V E

Set the ANC operation (p. 26) on or off.

Setting Range ACTIVE, BYPASS (default)

ACTIVE: Activates the ANC function.

BYPASS: ANC function does not work.

43

Page 43
Image 43
Vax M-9000 operating instructions A14 Operation mode setting when the ZP-001T is used, D E = P a G I N G P O R T