(C17) Lock status display

K E Y L O C K U N L O C K E D

Setting Range

UNLOCKED (default), LOCKED

The above screen displays the current key lock status.

When a key other than the Utility key is locked, "UNLOCKED" is indicated. If a locked key is pressed, the display changes to the password entry screen. To enter the key lock setting flow, press the Enter key.

For the setting items, refer to p. 78 "Key lock function setting items."

(C18) Password setting

S E T P A S S W O R D

_ _ _ _

Passwords can be set only when the keys are not locked.

Use the Input channel selection key to set the password and use the Left and Right shift keys to move characters. For password setting procedure, refer to p. 80 "Password setting."

(C19) GATE release time setting

G A T E R E L E A S E T I M E 5

Sets the time (seconds) required for the muted signal to return to the original level after the GATE activating input signal decreases below the threshold level.

Setting Range

1 – 8 (default: 5)

(C20) Communication speed (bps) setting

S E R I A L S P E E D = 5 7.6

Setting Range

9.6 k, 19.2 k, 38.4 k, 57.6 k (default), 115.2 k

(C21) Slot number selection and 900 series module classification setting

S L O T 1 = O T H E R S

Setting Range

Slot Number

1 – 8 (default: 1)

 

 

Module Classification

OTHERS (default), B-01, B-11, B-21, B-41, E-03, E-04, E-05,

 

E-06, E-07, L-01, L-11, L-41, M-01, M-03, M-11, M-21, M-41,

 

M-51, M-61, S-01, S-02, S-04, S-20S, T-01, T-02, T-12, U-01,

 

U-03, U-11, U-12, U-13, U-14, U-21, U-43, U-61, V-01, ML-11T,

 

NONE

 

 

Use the Left and Right shift keys to move the setting items on the screen.

For slots equipped with 9000 Series plug-in modules, their module model numbers are automatically displayed and cannot be changed. For slots equipped with 900 Series input modules, select their model numbers using the Parameter setting knob.

The settings performed here are merely displayed, and have no effect on the audio input and other settings. Setting the open slot to NONE extinguishes the indicators of the corresponding Input channel and its subsequent channels on the front panel. Besides, the channels do not appear on any setting screen.