Vulcan-Hart VCE10F 126179, VCE20H 126172, VCE10H 126178 Thermal Fuses, Steam Generator

Models: VCE10F 126179 VCE20F 126173 VCE6H 126177 VCE10H 126178 VCE20H 126172

1 68
Download 68 pages 25.58 Kb
Page 14
Image 14
Steam Generator

ELECTRIC COMBI OVEN - REMOVAL AND REPLACEMENT OF PARTS

Steam Generator

1.Turn off the water supply to the steam generator.

2.Remove the right side panel as outlined under

“COVERS AND PANELS”.

3.Remove the thermal fuse and protective sleeve from the heater thermowell.

4.Disconnect the heating element lead wire connections.

5.Remove the heating element from the steam generator by removing the mounting nuts.

NOTE: When installing a new heater, use the supplied gasket and ensure the mating surfaces are clean.

6.Reverse procedure to install.

THERMAL FUSE(S)

2.Disconnect the thermal fuse(s) lead wire connections.

3.Remove the thermal fuse and protective sleeve from the heater thermowell.

4.Reverse procedure to install.

NOTE: When replacing thermal fuse, be sure to insert the protective sleeve and thermal fuse together. The protective sleeve must be inserted into the heater thermowell with the fuse to avoid chafing of the fuse leads.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Remove the right side panel as outlined under

“COVERS AND PANELS”.

NOTE: When replacing thermal fuse do not pull the lead wires apart. This may break the contact junction or damage the connections.