Vulcan-Hart VCE20H 126172 Electrical, MACHINE AMPERAGE 3 PHASE/ 60HZ, Model, Power, Per Line

Models: VCE10F 126179 VCE20F 126173 VCE6H 126177 VCE10H 126178 VCE20H 126172

1 68
Download 68 pages 25.58 Kb
Page 5
Image 5
Electrical

ELECTRIC COMBI OVENS - GENERAL

Electrical

 

 

MACHINE AMPERAGE (3 PHASE/ 60HZ) 1

 

 

 

 

 

 

MODEL

POWER

PER LINE 2

RECOMMENDED

 

CIRCUIT

 

(KW)

 

 

 

 

 

 

PROTECTION 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208V

240V

480V

208V

240V

480V

 

 

 

 

 

 

 

 

VCE6H

9

25

22

11

35

30

15

VCE10H

18

50

43

22

70

60

30

VCE10F

18

50

43

22

70

60

30

VCE20H

24

67

58

29

90

80

40

VCE20F

36

100

87

43

125

110

60

NOTES: 1. Amperage values in the table are nominal. Tolerance is +5/-10%.

2.Line currents must be measured in full power convection heat mode.

3.Complied in accordance with National Electric Code, ANSI/NFPA 70, latest edition.

MODEL

INDIVIDUAL AMPERAGE (3 PHASE/ 60HZ) 1

CONVECTION HEAT

2

 

STEAM GENERATOR HEAT 3

 

 

 

 

 

 

 

 

 

ELEMENTS

 

 

 

ELEMENTS

 

 

 

208V

240V

 

480V

 

208V

240V

480V

 

 

 

KW NO.

 

 

 

KW NO.

 

 

VCE6H

9

1

25

22

11

8

1

22

19

10

VCE10H

9

2

50

43

22

8

2

45

39

19

VCE10F

9

2

50

43

22

8

2

45

39

19

VCE20H

6

4

67

58

29

8

3

67

58

29

VCE20F

9

4

100

87

43

8

4

89

77

39

NOTES: 1. Amperage values in the table are nominal. Tolerance is +5/-10%.

2.Convection heater currents must be measured in full power convection heat mode.

3.Steam generator heater currents must be measured in full power steam mode.

Page 5 of 68

Page 5
Image 5
Vulcan-Hart VCE20H 126172 Electrical, MACHINE AMPERAGE 3 PHASE/ 60HZ, Model, Power, Per Line, Recommended, Circuit, 208V