ELECTRIC COMBI OVENS - GENERAL
Electrical
|
| MACHINE AMPERAGE (3 PHASE/ 60HZ) 1 | |||||
|
|
|
|
|
| ||
MODEL | POWER | PER LINE 2 | RECOMMENDED | ||||
| CIRCUIT |
| |||||
(KW) |
|
| |||||
|
|
|
| PROTECTION 3 | |||
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 208V | 240V | 480V | 208V | 240V | 480V |
|
|
|
|
|
|
|
|
VCE6H | 9 | 25 | 22 | 11 | 35 | 30 | 15 |
VCE10H
18
50
43
22
70
60
30
VCE10F
18
50
43
22
70
60
30
VCE20H
24
67
58
29
90
80
40
VCE20F
36
100
87
43
125
110
60
NOTES: 1. Amperage values in the table are nominal. Tolerance is
2.Line currents must be measured in full power convection heat mode.
3.Complied in accordance with National Electric Code, ANSI/NFPA 70, latest edition.
MODEL
INDIVIDUAL AMPERAGE (3 PHASE/ 60HZ) 1
CONVECTION HEAT | 2 |
| STEAM GENERATOR HEAT 3 | |||||
|
|
|
|
|
|
|
|
|
ELEMENTS |
|
|
| ELEMENTS |
|
| ||
| 208V | 240V |
| 480V |
| 208V | 240V | 480V |
|
|
| ||||||
KW NO. |
|
|
| KW NO. |
|
|
VCE6H
9
1
25
22
11
8
1
22
19
10
VCE10H
9
2
50
43
22
8
2
45
39
19
VCE10F
9
2
50
43
22
8
2
45
39
19
VCE20H
6
4
67
58
29
8
3
67
58
29
VCE20F
9
4
100
87
43
8
4
89
77
39
NOTES: 1. Amperage values in the table are nominal. Tolerance is
2.Convection heater currents must be measured in full power convection heat mode.
3.Steam generator heater currents must be measured in full power steam mode.
Page 5 of 68