Vulcan-Hart VCE20F 126173, VCE20H 126172, VCE6H 126177 Clean Cycle Mode - Steam Generator Deliming

Models: VCE10F 126179 VCE20F 126173 VCE6H 126177 VCE10H 126178 VCE20H 126172

1 68
Download 68 pages 25.58 Kb
Page 33
Image 33
CLEAN CYCLE MODE - STEAM

ELECTRIC COMBI OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

4.To adjust the buzzer volume, turn the buzzer volume adjustment screw until the desired volume is obtained.

5.Once the buzzer frequency and volume are set to the desired levels, press the START key to save the setting and exit the configuration mode.

CLEAN CYCLE MODE - STEAM

GENERATOR DELIMING

WARNING: THE OVEN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE OVEN. THE COOKING COMPARTMENT CONTAINS LIVE STEAM. STAY CLEAR WHEN OPENING DOOR.

Steam generator deliming should be done on a scheduled basis. The frequency depends on the quality of the local water supply and whether or not a water treatment system is used. Even with the use of a water treatment system, periodic deliming of the steam generator is still required.

On combi ovens using a water treatment system, follow the instructions for that system to delime the steam generator. Only use the type of chemical recommended or described in the deliming instructions for the system in use. If the Kleensteam water treatment system is used, Scalekleen is the recommended chemical.

If a water treatment system is not used, follow the instructions for deliming the steam generator using vinegar, as outlined in the steps below. See “WATER CONDITIONING” under “GENERAL”.

1.Programmable oven control - Press the ON key to turn the oven on and press the PROG key to enter the programed cooking mode. Program number “00" is displayed in the program display. Press the down key once, to select the clean cycle program or if at program 98 press the up key once to select the clean cycle program. Press and hold for automatic scrolling. “CC” is displayed in the program number display and “dSCL” is displayed in the temperature display. Press the START/STOP key to start the clean cycle and the start/stop LED turns on.

Manual oven controls - Turn the oven on and select the descale mode by rotating the selector knob to dSCL. “dSCL” is displayed in the temperature display and the clean cycle starts automatically.

2.The steam generator begins a normal drain cycle.

A.At the end of the drain cycle, oven beeps for 10 seconds. On the programmable oven control, the start/stop LED turns off.

B.“40" minutes is displayed in the time display and “dSCL” is displayed in the temperature display.

3.Add the deliming chemical.

A.If a water treatment system is installed in the water line to the steam generator.

1)Turn the water supply off.

2)Press the relief valve at the top of the feeder bowl head to relieve system pressure.

3)Unscrew the feeder bowl (clear) from the head and remove cartridge from the bowl.

4)Remove the dip from its holding clip and insert the dip tube (o-ring first) in to the center port.

5)Add the appropriate amount of deliming chemical to the feeder bowl for the combi model and mix the contents of the bowl with water. See table below.

NOTE: Do not exceed the chemical amounts listed in the table below or provided with the deliming chemical for the water treatment system in use.

6)Replace the feeder bowl.

7)Turn the water supply on.

Page 33 of 68

Page 33
Image 33
Vulcan-Hart VCE20F 126173, VCE20H 126172, VCE10H 126178, VCE6H 126177 Clean Cycle Mode - Steam Generator Deliming