Vulcan-Hart VCE10F 126179 KM5 5CON, KM6 6CON, KM7 7CON, 2HTR Heating Element 3HTR Heating Element

Models: VCE10F 126179 VCE20F 126173 VCE6H 126177 VCE10H 126178 VCE20H 126172

1 68
Download 68 pages 25.58 Kb
Page 39
Image 39
KM5 (5CON)

 

ELECTRIC COMBI OVEN - ELECTRICAL OPERATION

KM5 (5CON)

. . . . . . . Contactor for steam generator heating elements; (7HTR) on 20 level half

 

and (8HTR) on 20 level full only.

KM6 (6CON)

. . . . . . . Contactor for convection heating elements; (1HTR) on 6 level; (1HTR)

 

inner on 10 level; (1HTR) Inner top and (5HTR) inner bottom on 20 level.

KM7 (7CON)

. . . . . . . Contactor for convection heating elements; (3HTR) outer on 10 level;

 

(3HTR) outer top and (6HTR) outer bottom on 20 level.

1HTR Heating Element . . . . . . . . . Single convection heating elements on 6 level; Inner on 10 level and 20 level (top).

2HTR Heating Element . . . . . . . . .

3HTR Heating Element . . . . . . . . .

4HTR Heating Element . . . . . . . . .

5HTR Heating Element . . . . . . . . .

6HTR Heating Element . . . . . . . . .

7HTR Heating Element . . . . . . . . .

8HTR Heating Element . . . . . . . . .

Steam generator heating elements on 6, 10 and 20 level.

Outer convection heating elements on 10 level and 20 level (top).

Steam generator heating elements on 10 and 20 level.

Inner convection heating elements on 20 level (bottom).

Outer convection heating elements on 20 level (bottom).

Steam generator heating elements on 20 level 1/2 size.

Steam generator heating elements on 20 level full size.

NOTE: The relay’s below are mounted on the relay board and are not individually replaceable.

K1 Door Relay . . . . . . . . . . . . . . . .

K2 Vent Relay . . . . . . . . . . . . . . . .

K3 On-Off Relay . . . . . . . . . . . . . .

K4 Water Injection Relay . . . . . . .

K5 Water Fill Relay . . . . . . . . . . . .

K6 Half Power

Full Speed Relay . . . . . . . . . . . . .

K7 Half Power

Half Speed Relay . . . . . . . . . . . . .

K8 Steam Regulation Relay . . . . .

K9 Convection Heat Relay . . . . . .

K10 Convection Heat Relay . . . . .

Controls power to door motor(s).

Controls power to cavity vent motor.

Controls power to component cooling fan(s) and supplies power to one side of K4, K5, and K6, K7, K8, K9 and K10 through the thermal fuses and high limit thermostats.

Controls power to water injection solenoid valve (humidifier) and door light when K3 is ON.

Controls power to water fill solenoid valve (when K3 is ON) and drain pump motor (when K3 is OFF).

Controls power to contactor KM1. This relay is energized along with K7 for full power full speed operation, and is also energized in half power speed half mode. When half power half speed mode is selected, relay K6 is energized.

Controls power to contactor KM2. This relay is energized along with K6 for full power full speed operation. When half power half speed mode is selected, relay K7 is not energized. On 20 level models only, controls power to contactor KM3 for steam generator heating elements, and powers 2SOL drain cool down solenoid.

Controls power to KM3 for steam generator heating elements, and powers 2SOL drain cool down solenoid valve on 6 & 10 levels. On 20 level models only, controls power to contactor KM5.

Controls power to KM6 for convection heating elements; (1HTR) single on 6 level ;(1HTR) inner on 10 level; (1HTR) inner top and (5HTR) inner bottom on 20 level.

Controls power to KM7 for convection heating elements ; (3HTR) outer on 10 level; (3HTR) outer top and (6HTR) outer bottom on 20 level.

Page 39 of 68