Vulcan-Hart VCE10H 126178, VCE20H 126172, VCE6H 126177, VCE20F 126173, VCE10F 126179 Steam Mode

Models: VCE10F 126179 VCE20F 126173 VCE6H 126177 VCE10H 126178 VCE20H 126172

1 68
Download 68 pages 25.58 Kb
Page 46
Image 46
Steam Mode

ELECTRIC COMBI OVEN - ELECTRICAL OPERATION

3.Press the temp key to set the operating temperature (default setting is 302°F; adjustable range is 35 to 518°F).

A.Press the temperature up or down keys to adjust the setting.

4.Start/Stop key is pressed to begin the cooking cycle.

A.Start/Stop LED on.

B.Convection heating elements energized and cycle as described under “HEATING REGULATION”.

C.Steam generator pre-heats (initial start up only) as described under “STEAM PRE- HEAT”.

NOTE: When degree symbol shows in the temperature display, convection and/or steam generator heating elements are energized.

1)Drain cool down solenoid energized.

NOTE: Whenever steam generator heating elements are on, the drain cool down solenoid is energized.

D.Cavity fan motor(s) energized.

5.Oven control monitors cavity temperature and cycles the convection heating elements as necessary, to maintain set point temperature.

6.Start/Stop key is pressed to end cooking cycle.

A.Start/Stop LED off.

B.Convection heating elements de- energized.

C.Cavity fan motor(s) de-energized.

D.Convection mode remains selected with LED on.

E.Cavity vent remains closed.

F.The operating temperature remains as entered unless the heating mode or operating temperature setting is changed or the oven is turned off.

Steam Mode

1.Conditions exist as described in “POWERING CONTROL”.

2.Steam key is pressed.

A.Steam LED turns on and “- h - - min” is displayed in the time display.

B.Cavity set point temperature (default) is displayed in the temperature display then reverts to the actual cavity temperature.

C.Steam generator fill solenoid is energized until proper water level is reached then turns off. See “WATER LEVEL SENSORS” under “COMPONENT FUNCTION”.

D.First LED for the cooking program phase flashes.

3.Press the temp key to set the operating temperature. The default temperature displayed (195 to 212°F) is pre-selected in the configuration mode and is the steam temperature setting (boiling point adjustment) for elevation. The adjustable operating range is 35 to 212°F. See “CONFIGURATION MODE - PROGRAMMABLE CONTROL” under

“SEQUENCE OF OPERATION”.

A.Press the temperature up or down keys to adjust the setting.

4.Start/Stop key is pressed to begin the cooking cycle.

A.Start/Stop LED on.

B.Steam generator heating elements energized and cycle as described in “STEAM MODE” under “STEAM REGULATION”.

NOTE: When degree symbol shows in the temperature display, steam generator heating elements are energized.

1)If oven cavity temperature is below set point temperature, the steam generator heating elements turn on at full power until steam temperature is reached, then turn off.

a.Drain cool down solenoid energized.

NOTE: Whenever steam generator heating elements are on, the drain cool down solenoid is energized.

2)If oven cavity temperature is above set point temperature, the oven performs an automatic cool down as described under “WATER INJECTION (HUMIDIFIER)”, then the steam generator heating elements turn on.

C.Cavity fan motor(s) energized.

5.Oven control monitors cavity temperature and cycles the steam generator heating elements as necessary, to maintain set point temperature.

6.Start/Stop key is pressed to end the cooking cycle.

Page 46 of 68

Page 46
Image 46
Vulcan-Hart VCE10H 126178, VCE20H 126172, VCE6H 126177, VCE20F 126173, VCE10F 126179 service manual Steam Mode