STEAM GENERATOR DRAIN

ELECTRIC COMBI OVEN - REMOVAL AND REPLACEMENT OF PARTS

STEAM GENERATOR DRAIN

 

VENT DAMPER ASSEMBLY

PUMP

 

 

1.Turn off the oven and allow the steam generator to drain.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

2.Turn off the water supply.

3.Remove the right side panel as outlined under

“COVERS AND PANELS”.

4.Disconnect lead wires and hoses connected to the drain pump.

5.Remove the bolts from the mounting bracket that secure the pump.

6.Reverse procedure to install.

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

VENT DAMPER ASSEMBLY DIAGRAM

Vent Motor

1.Remove the right side panel as outlined under

“COVERS AND PANELS”.

2.Disconnect the lead wires from the switch and motor.

3.Remove the screw and nut behind the motor assembly that connects motor to shaft extension rod.

4.Remove the motor and switch assembly from the oven by sliding the mounting bracket out from the oven frame.

5.Reverse procedure to install.