44 MIXING Display Functions

Digital Recording Console 02R User’s Guide
View
The VIEW display function allows you to see all the parameters of an
individual channel at a glance and adjust any parameter that you feel
requires a change. You can view the input channels (MIC/LINE 1 through
16, LINE 17/18 through 23/24) and the tape and effect return channels
(TAPE 1 through 16, EFF1 and EFF2).
Display Screen
Shown below is the VIEW display function:
Unlike the previous display functions in this section, the VIEW display
function shows the currently selected channel only.

Phase/Attenuation

Each time you press the [ENTER] button, the phase will alternate between
NOR (normal) and REV (inverted). Rotate the encoder wheel to adjust the
attenuation.
These controls duplicate the phase/attenuation function. See “Phase and
Attenuation” on page 32 of the User’s Guide.

Pan

Rotate the encoder wheel to set the pan position. You may find the PAN
controls in the SELECTED CHANNEL group more convenient for setting
the pan position.
When you press the [ENTER] button, the channel will be linked with its
adjacent channel in GANG mode. Dotted lines will indicate the connection
to the corresponding channel. Press the [ENTER] button again to switch
back to INDIVIDUAL mode.
See “Pan and Balance” on page 36 and “Stereo-Pair Pans” on page 37 of the
User’s Guide.
1. Press the [VIEW] button.
The VIEW display
function appears.
2. Select a channel by
pressing one of the [SEL]
buttons.
3. Use the CURSOR buttons
to select an item.
4. Adjust the value of the
item using the encoder
wheel and/or the
[ENTER] button.
5. To set the EQ, use the
CURSOR buttons to
select the EQ curve and
press the [ENTER] button.
The 02R will switch to the
EQUALIZER display
function.
6. To set the dynamics,
select the dynamics
curve with the CURSOR
buttons and press the
[ENTER] button. The 02R
will switch to the
DYNAMICS display
function.
VIEW