66 Dynamics

Digital Recording Console 02R User’s Guide
Compander
A compander is a compressor-expander - a combination of signal
compression and expansion. The compander attenuates the input signal
above the threshold as well as the level below the width. For very dynamic
material, this program allows you to retain the dynamic range without
having to be concerned with excessive output signal levels and clipping.

CompanderH (CPH) and CompanderS (CPS)

parameters:

Threshold determines the level of input signal required to trigger the
compander. Signals above the threshold pass through unaffected. Signals at
and below the threshold level are attenuated by the amount specified using
the Ratio parameter. The trigger signal is determined using the KEY IN
parameter.
Ratio controls the amount of companding - the change in output signal
level relative to change in input signal level. With a 2:1 ratio, for example, a
10 dB change in input level (above the threshold) results in a 5 dB change in
output level. The hard compander (CPH) has a fixed ratio of 5:1 for
expansion and the soft compander (CPS) has a fixed ratio of 1.5:1 for
expansion.
Attack controls how soon the signal is companded once the compander has
been triggered. With a fast attack time, the signal is companded almost
immediately. With a slow attack time, the initial transient of a sound passes
through unaffected.
Out Gain sets the compander’s output signal level.
Width is used to determine the distance, in decibels, between the expander
and the compressor. With a width of 90dB, the expander is effectively
switched off and the compander is simply a compressor-limiter. With a
smaller width (30dB) and a high threshold (0dB), the compander is an
expander-compressor-limiter.
Release determines how soon the compander returns to its normal gain
once the trigger signal level drops below the threshold.
Parameter Value
Threshold (dB) –54 to 0 (55 points)
Ratio 1.0, 1.1, 1.3, 1.5, 1.7, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0, 6.0, 8.0,
10, 20 (15 points)
Attack (ms) 0 to 120 (121 points)
Outgain (dB) –18 to 0 (36 points)
Width (dB) 1 to 90 (90 points)
Release (ms) 5 ms to 42.3 sec *1, 6 ms to 46.0 sec *2,
8 ms to 63.4 sec *3 (160 points)
*1 These values are obtained when the sampling frequency is 48kHz.
*2 These values are obtained when the sampling frequency is 44.1 kHz.
*3 These values are obtained when the sampling frequency is 32 kHz
-70
-60
-50
-40
-30
-20
-10
0
+10
+20
-70 -60 -50 -40 -30 -20 -10 0 +10+20
Input Level
Output Level
d
B
dB
Threshold
Width