204 Specifications

Digital Recording Console 02R User’s Guide
Error Messages
Follow the corrective actions described below when the error messages are shown on the display:
Error Message Corrective Action
2TR-D1 No Input! Correct digital signal is not input to 2TR-D1.
(C-R monitoring is not available.)
2TR-D2 Cascade Disabled 2TR-D2 cannot be routed to STEREO BUS.
(Incorrect word clock setting)
2TR-D2 No Input! Correct digital signal is not input to 2TR-D2.
(C-R monitoring is not available.)
2TR-D3 No Input! Correct digital signal is not input to 2TR-D3.
(C-R monitoring is not available.)
Automix Aborted! Automix data was aborted.
(You can undo the operation.)
Automix Disabled! Time code was input, but automix is disabled.
Automix REC Ready! Ready for recording automix.
Automix Recording! Recording automix now.
Automix Running! Automix is now running.
Automix Updated! Automix has been updated.
(You can undo the operation.)
Byte Count Error! Byte count for the received bulk data is not correct.
Can't assign 2TR-D1! 2TR-D1 cannot be routed to line 17/18. (The signal at 2TR-D1 is not
syncing with the 02R, or 2TR-D1 has been selected in the C-R monitor
section.)
Can't assign 2TR-D2! 2TR-D2 cannot be routed to line 19/20. (The signal at 2TR-D2 is not
syncing with the 02R, or 2TR-D2 has been selected in the C-R monitor
section.)
Can't select SLOT3! SLOT3 cannot be selected for digital input.
(The I/O card is not in SLOT3.)
Can't select SLOT4! SLOT4 cannot be selected for digital input.
(The I/O card is not in SLOT4.)
Can't select WORD CLOCK! Not available as a word clock source.
Cannot Copy Title! You cannot copy the title from the memory that has no data.
Cannot Paste Title! You cannot paste the title to the memory that has no data.
Check Sum Error! Check sum of the received bulk data is not correct.
Code Mismatch! Product code for the received bulk data is not correct.
DIGITAL I/O Error!
Incoming signal from SLOT DIO is not syncing with the 02R. The syn-
chronization system has not been configured successfully. Or, if the
sync system has been configured, this message may still appear if the
clock sent from the MTR is unstable until the digital MTR enters CHASE
status. You can select whether this message will be shown or not. (see
“Preferences” on page 162 of the User’s Guide)
Duplicate Grouping! You cannot duplicate the group.