76 Dynamics

Digital Recording Console 02R User’s Guide
Dynamics
Preset Dynamics Program Parameters

The “Release”, “Hold”, and “Decay” values shown in the following table are valid when the 02R is set at a

sampling frequency of 44.1kHz.

No. Name Type Parameter Value Description
1 A.Dr.BD "CMP Compressor
Threshold (dB) –24 Compressor that gives the best
results with an acoustic bass drum.
Ratio ( :1) 3
Attack (ms) 9
Outgain (dB) 5.5
Knee 2
Release (ms) 58
2 A.Dr.BD "EXP Expander
Threshold (dB) –23 Expander for the same purpose as
program 1.
Ratio ( :1) 1.7
Attack (ms) 1
Outgain (dB) 3.5
Knee 2
Release (ms) 70
3 A.Dr.BD "GAT Gate
Threshold (dB) –11 Gate for the same purpose as
program 1.
Range (dB) –53
Attack (ms) 0
Hold (ms) 1.93
Decay (ms) 400
4 A.Dr.BD "CPH CompanderH
Threshold (dB) –11 Hard compander for the same
purpose as program 1.
Ratio ( :1) 3.5
Attack (ms) 1
Outgain (dB) –1.5
Width (dB) 7
Release (ms) 192
5 A.Dr.SN "CMP Compressor
Threshold (dB) –17 Compressor that gives the best
results with an acoustic snare
drum.
Ratio ( :1) 2.5
Attack (ms) 8
Outgain (dB) 3.5
Knee 2
Release (ms) 12
6 A.Dr.SN "EXP Expander
Threshold (dB) –23 Expander for the same purpose as
program 5.
Ratio ( :1) 2
Attack (ms) 0
Outgain (dB) 0.5
Knee 2
Release (ms) 151