Y-axis moveable mechanical stopper

CHAPTER 4 Adjustment

11)Go out of the safeguard enclosure, and check that no one is inside the safe- guard enclosure. Then turn on the controller.

12)Perform the absolute reset from outside the safeguard enclosure.

13)After completing absolute reset, check the machine reference value.

14)If the machine reference value is in the range between 40 and 60 (recom- mended range), then the machine reference has been completely adjusted. If it is outside the recommended range, then repeat the procedure that starts in 5) to readjust it.

Y-axis moveable mechanical stopper

BBolt (On back side of arm)Fig. 4-10 Adjustment of Y-axis machine referenceA

X-axis arm

Bolt (On back side of arm)

Fig. 4-10 Adjustment of Y-axis machine reference

4-26

Page 104
Image 104
Yamaha YK180X, YK120X 10 Adjustment of Y-axis machine reference, Y-axis moveable mechanical stopper BA X-axis arm