3 Protective Bonding

CHAPTER 3 Installation

3 Protective Bonding

(Symbol 417-IEC-5019)WARNING

Be sure to ground the robot and controller to prevent electrical shock.

Manual backgroundWARNING

Turn off the controller before grounding the robot.

The robot must be grounded as follows:

1)Provide a terminal marked "PE" for the protective conductor of the entire system and connect it to an external protective conductor. In addition, se- curely connect the ground terminal on the robot pedestal to the same protec- tive conductor. (See Fig. 3-6.)

(Symbol 417-IEC-5019)

2)When the end effector uses an electrical device which, if it malfunctions, might make contact with the power supply, the user must provide proper grounding on his own responsibility. The YK-X series robots do not have a ground terminal for this purpose.

3)For details on protective bonding on the robot body to comply with CE mark- ing, follow the instructions on protective bonding explained in the "YAMAHA robot controller owner's manual" or "CE marking manual".

4)Use a ground cable with a conductor wire cross section of at least 2.0mm2 and a length within 1 meter.