Troubleshooting

Communications Diagnostics

The following example of a communications DUMP mode printed out. The printout displays hexadecimal data 00h-FFh (0-255 decimal) with a unique character for each hexadecimal value displayed above the hexadecimal data.

The blank lines between the lines of data are where serial port and Bluetooth data handling errors get logged. The errors are:

F = Frame Error

P = Parity Error

N = Noise Error

O = Data Overrun Error

To exit the diagnostic mode and resume printing, turn off and then turn on the printer. An alternate method for exiting the diagnostic mode is to press the Feed button as many times as it takes to clear the printer’s command buffer and print ‘Out of DUMP’ on the label.

95

8/4/10

GX420d™ / GX430d™ User Guide

980611-001 Rev. C

Page 107
Image 107
Zebra Technologies GX420D, GX430D manual Communications Diagnostics