Zebra Technologies GX430D, GX420D manual Manual Calibration

Models: GX420D GX430D

1 128
Download 128 pages 10.03 Kb
Page 104
Image 104

92

Troubleshooting

Manual Calibration

Manual Calibration

Manual calibration is recommended whenever you are using pre-printed media or if the printer will not correctly auto calibrate.

1.Make sure media is loaded.

2.Turn on the printer power.

3.Press and hold the Feed button until the green status light flashes once, then twice and then continuing until the flash groups reach the group of seven flashes. Release the Feed button.

4.The printer will set the media sensor for the label backing being used. After it is done making this adjustment, the roll will automatically feed until a label is positioned at the printhead. A profile of the media sensor settings (similar to the example below) will print. Upon completion, the printer will save the new settings in memory and the printer is ready for normal operation.

5.Press the Feed button. One entire blank label will feed. If this does not happen, try defaulting (refer to the four-flash sequence in “Feed Button Modes” later in this chapter) and recalibrating the printer.

Note • Performing a manual calibration disables the auto calibration function. To return to auto calibration, default the printer (refer to the four-flash sequence in Feed Button Modes on page 96 in this section).

980611-001 Rev. C

GX420d™ / GX430d™ User Guide

8/4/10

Page 104
Image 104
Zebra Technologies GX430D, GX420D manual Manual Calibration