(UURU￿FRQGLWLRQ￿³￿+($'￿23(1

Problem

Solution

The printhead is not fully closed.

Close the printhead.

 

 

The ribbon is loaded incorrectly; it is covering

Correctly align the ribbon with the guide mark on the ribbon

the head open sensor.

guide plate before closing the printhead assembly. See

 

“Ribbon Loading” on page 34.

 

 

(UURU￿FRQGLWLRQ￿³￿5,%%21￿,1

Problem

Solution

 

Via the front panel, locate the “PRINT METHOD” menu item

 

(page 42) and select thermal transfer mode.

Print method is incorrectly set.

 

Ensure that the printer driver and/or software settings are

 

correctly set (if applicable).

 

 

 

Remove the ribbon and set the printer to direct thermal

 

mode. (See “PRINT METHOD” on page 42.)

The ribbon is loaded.

 

Ensure that the printer driver and/or software settings are

 

correctly set (if applicable).

 

 

:DUQLQJ￿³￿+($'￿29(5￿7(03

Problem

Solution

 

Allow the printer to cool. Printing automatically resumes

The printhead is over temperature.

when the printhead elements cool to an acceptable

 

operating temperature.

 

 

:DUQLQJ￿³￿+($'￿81'(5￿7(03

Problem

Solution

 

Continue printing while the printhead reaches the correct

 

operating temperature.

The printhead is under temperature.

 

The environment may be too cold for proper printing.

 

Relocate the printer to a warmer area.

 

 