Technical Reference for ZyXEL omni.net series

The three levels of security used in conjunction with the security types are described in the following table.

 

 

 

 

Level 1

 

 

Level 2

 

 

Level 3

 

Password

 

Yes

 

Yes

 

Yes

 

Check

 

 

 

 

 

 

 

 

 

 

 

 

 

CPN Check OK

 

N/A

 

Call back

 

 

 

and S119.6=0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPN Check OK

 

N/A

 

Keep the connection

 

 

 

and S119.6=1

 

 

 

Prompts the remote user to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enter call back number

 

CPN

 

N/A

 

Disconnect

 

 

 

 

 

for calling back.

 

nmatched

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPN not

 

N/A

 

Call back using the

 

 

 

Available

 

 

corresponding pre-stored

 

 

 

 

 

 

 

 

 

 

number

 

 

 

AT Commands

[AT*G1] for Type 1 security

 

[AT*G2] for Type 1 security

[AT*G5] for Type 2 security

 

 

 

 

 

[AT*G3] for Type 2 security

 

[AT*G4] for Type 2 security

 

 

 

Level 1 security

 

 

 

 

 

Level 3 security

 

Will only perform password checking.

 

 

 

Once the password is

 

With Level 1 security, the local omni.net ISDN

 

 

 

matched the local omni.net

 

TA will maintain the connection if the password is

 

 

 

ISDN TA will prompt the

 

matched, otherwise the line will be disconnected.

 

 

 

remote user to enter a call

 

 

 

 

 

 

 

 

 

 

back number.

 

Level 2 security

 

 

 

 

 

 

 

 

Provides Calling Party Number checking and Callback. The callback number is

 

 

 

pre-stored in the password table.

 

 

 

 

 

If the password has been matched (in a maximum of 3 tries over a 40 second

 

 

 

time period) with its pre-stored password list, the local omni.net ISDN TA will

 

 

 

check the Calling Party Number (CPN) against the pre-stored number

 

 

 

corresponding to the password. If they are matched, the local TA will choose

 

 

 

either to keep the connection or to disconnect and then call back according to

 

 

 

the setting of bit 6 of S119:

 

 

 

 

 

 

# S119.6=0 - Disconnect and then call back.

 

 

 

 

 

 

# S119.6=1 - Keep the connection.

 

 

 

 

 

If the CPN does not match with what is stored in the table, the local omni.net

 

 

 

ISDN TA will disconnect the call. If CPN is unavailable in the SETUP message,

 

 

 

the local omni.net will disconnect the call and

then call back using the

 

 

 

pre-stored number corresponding to the dial-in password.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 54. three levels of security