Technical Reference for ZyXEL omni.net series

Basic S-Registers 'ATSn=x'

All the Following Commands Require a 'AT' Prefix

 

S Com.

 

 

Function & Description

 

 

+Definition

 

S0=

 

 

Set the number of rings on which the omni.net will answer.

 

+000

 

 

 

 

 

A '0' value disables auto-answer.

 

 

 

 

 

 

 

 

 

 

 

S1=

 

 

Counts and stores number of rings from an incoming call.

 

+000

 

 

 

 

 

 

 

 

S2=

 

 

Define escape code character, default <+> (43 dec.).

 

+043

 

 

 

 

 

 

 

 

S3=

 

 

Define ASCII Carriage Return.

 

+013

 

 

 

 

 

 

 

 

S4=

 

 

Define ASCII Line Feed.

 

+010

 

 

 

 

 

 

 

 

S5=

 

 

Define ASCII Backspace.

 

+008

 

 

 

 

 

 

 

 

S7=

 

 

Set duration, in number of seconds, omni.net waits for a connection.

 

+060

 

 

 

 

 

 

 

 

S8=

 

 

Set duration, in seconds, for pause (,) option in Dial command and pause

 

+002

 

 

 

 

 

between command re-executions for Repeat (>) command.

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 73. Basic S-Registers 'ATSn=x'

B-5