Technical Reference for ZyXEL omni.net series

All the Following Commands Require a 'AT' Prefix

 

S Com.

 

 

bit

 

 

dec

 

 

hex

 

 

Function and description

 

 

+Def./Ref.

 

S29=

 

 

 

0-39

0-39

 

Set default dial phone number pointer, use 'AT&Zn=s' to

+000 *D

 

 

 

 

 

 

 

 

 

 

 

 

 

store phone numbers.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S31=

 

 

 

0-25

 

0-FF

 

 

Holds the ASCII decimal value of the XON.

+017

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

S32=

 

 

 

0-25

 

0-FF

 

 

Holds the ASCII decimal value of the XOFF.

+019

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

S35=

 

 

bit

 

 

dec

 

 

hex

 

 

Bit mapped register

 

 

 

 

6

64

30

 

Enable password protection to profile saving, when

&Wn

 

 

 

 

 

 

 

 

 

 

 

 

 

<AT&Wn> is issued, and the 'n' profile in the memory has

 

 

 

 

 

 

 

 

 

 

 

 

 

 

this bit on, supervisory password will be requested.

 

 

 

 

7

128

60

 

Enable extended numerical result codes from 50-71 when

V0

 

 

 

 

 

 

 

 

 

 

 

 

 

an error corrected connection is made. Use with 'ATV0' (see

S23b6

 

 

 

 

 

 

 

 

 

 

 

 

 

result code table).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S36=

 

 

bit

 

 

dec

 

 

hex

 

 

Bit mapped register

+000

 

 

 

5-7

 

 

 

 

 

 

 

 

Security function control register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 (*)

0

 

 

Disable security function.

*G0

 

 

 

 

 

 

32

20

 

Enable type 1 security, with password check (Proprietary).

*G1

 

 

 

 

 

 

64

40

 

 

Enable type 1 security, with password check and callback

*G2

 

 

 

 

 

 

 

 

 

 

 

 

 

(Proprietary).

 

 

 

 

 

 

 

96

60

 

Enable type 2 security, with password check.

*G3

 

 

 

 

 

 

128

80

 

 

Enable type 2 security, with password check and callback.

*G4

 

 

 

 

 

 

160

 

 

A0

 

 

Enable type 2 security, with password check and callback.

*G5

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote site enters the callback number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S38=

 

 

bit

 

 

dec

 

 

hex

 

 

Bit mapped register

+000

 

 

 

0

1

1

 

Repeatedly dialing default number.

*Dn, S29

 

 

 

1-2

 

 

 

 

 

 

 

 

Reserved.

 

 

 

 

2

4

4

 

Key for ATSWR, ATHWR.

 

 

 

 

3

8

8

 

DCD on/off sequence follows UNIX standard, DCD high

&C1 S21b4

 

 

 

 

 

 

 

 

 

 

 

 

 

before connect message is sent, DCD off after last DCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

response is sent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S40=

 

 

bit

 

 

dec

 

 

hex

 

 

Bit mapped register

+000

 

 

 

1

2

2

 

No result code displayed in answer mode.

Q2

 

B-9