Technical Reference for ZyXEL omni.net series

Extended 'AT*' Command Set

All the Following Commands Require a 'AT' Prefix

 

AT Com.

 

Options

 

Function & Description

 

Reference

 

*Cn

 

 

 

Character length, including start, stop and parity bit.

 

S15b3-4

 

 

 

 

*C0 (*)

 

DTE port 10-bit character length.

 

 

 

 

 

 

 

 

 

 

 

*Dn

 

n=0-39

 

Set default dial pointer at telephone directory location 'n'.

 

S29

 

 

 

 

*D0 (*)

 

(See also S35b4 and S38b0)

 

 

 

 

 

 

 

 

 

 

 

*Gn

 

 

 

Security function selection.

 

S36b5-7

 

 

 

 

*G0 (*)

 

Disable security function.

 

 

 

 

 

 

*G1

Enable type 1 security, with password check (Proprietary).

 

 

 

 

 

 

*G2

 

Enable type 1 security, with password check and call back

 

 

 

 

 

 

 

(Proprietary).

 

 

 

 

 

 

*G3

Enable type 2 security, with password check.

 

 

 

 

 

 

*G4

 

Enable type 2 security, with password check and call back.

 

 

 

 

 

 

*G5

 

Enable type 2 security, with password check and call back,

 

 

 

 

 

 

 

remote site enters the call back number.

 

 

 

*GCn

 

n=0-1

 

Call-back function selection.

 

S119b0

 

 

 

 

*GC0 (*)

 

Disable call-back function.

 

 

 

 

 

 

*GC1

Enable call-back function.

 

 

 

 

 

 

 

 

 

 

 

*HCn

 

n=0-4

 

Assign call-back phone number, 's' to storage location, 'n'.

 

 

 

 

 

 

 

 

 

 

 

*Hn

 

n=0-39

 

Modify user password table at location 'n'.

 

 

 

 

 

 

 

 

 

 

*HS

 

 

Modify supervisory password (Default:: See User's Manual)

 

 

 

 

 

 

 

 

 

 

 

*T

 

 

 

Recall the last CND (Caller ID) information.

 

 

 

 

 

 

 

 

 

 

 

*V

 

 

 

View the password table.

 

 

 

 

 

 

 

 

 

 

*VC

 

 

View the call-back number table.

 

 

 

 

 

 

 

 

 

 

 

Fax *VC

 

 

 

View the call-back number table.

 

 

 

Table 71. Extended 'AT*' Command Set

A-16