Technical Reference for ZyXEL omni.net series

Fax Command

All the Following Commands Require a 'AT' Prefix

AT

Com.

 

Value

 

Function & Description

 

Reference

 

+FCLASS=n

 

 

 

Service class selection

 

FAX CLASS 1

 

 

 

 

n=0

 

Sets to modem mode.

 

 

 

 

 

 

n=1

 

Sets to Class 1 mode

 

 

 

+FTS=n

0-255

 

Stops transmission and pauses, in 10ms units.

 

 

 

+FRS=n

0-255

 

Waits for silence, in 10ms units.

 

 

 

+FTM=<MOD>

 

 

 

Transmits data with a <MOD> carrier.

 

 

 

+FRM=<MOD>

 

 

 

Receives data with a <MOD> carrier.

 

 

 

+FTH=<MOD>

 

 

 

Transmits HDLC data with a <MOD> carrier.

 

 

 

+FRH=<MOD>

 

 

 

Receives HDLC data with a <MOD> carrier.

 

 

 

Table 71a. Fax Command

The <MOD> parameter takes on the following values:

Modulation values

Value

 

Modulation

 

Speed

 

Requirements

 

 

3

 

V. 21 ch. 2

 

300

 

Required for FTH &FRH

 

 

 

 

 

 

 

 

 

24

 

V. 27ter

 

2400

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

48

 

V. 27ter

 

4800

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

72

 

V. 29

 

7200

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

73

 

V. 17

 

7200

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

74

 

V. 17 w/st

 

7200

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

96

 

V. 29

 

9600

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

97

 

V. 17

 

9600

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

98

 

V. 17 w/st

 

9600

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

121

 

V. 17

 

12000

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

122

 

V. 17w/st

 

12000

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

145

 

V. 17

 

14400

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

146

 

V. 17w/st

 

14400

 

Required for FTH & FRH & FTM & FRM

 

 

 

 

 

 

 

 

 

 

*w/st means with V. 17 short training

Table 71b. Modulation values

A-17