Technical Reference for ZyXEL omni.net series

All the Following Commands Require a 'AT' Prefix

 

S Com.

 

 

bit

 

 

dec

 

 

hex

 

 

Function and description

 

 

+Def./Ref.

 

S84=

 

 

bit

 

 

dec

 

hex

 

 

 

 

 

 

 

 

 

0-2

 

 

 

 

 

 

 

 

Embedded Protocol Analyzer control.

CCn

 

 

 

0

1

1

 

Capture DTE-DCE interface protocol information.

 

 

 

 

1

2

2

 

Capture B-channel (X.75 or V.120) frames.

 

 

 

 

2

4

4

 

Capture D-channel protocol information.

 

 

 

 

3

0

0 (*)

 

 

Display S register value in decimal format.

 

 

 

 

 

 

 

8

8

 

Display S register value in hex format.

 

 

 

 

4

0 (*)

0

 

 

Indicate Caller ID after the 1st RING message.

 

 

 

 

 

 

 

16

10

 

Disable Caller ID indication.

 

 

 

 

5

0

0

 

POTS port 1 has higher priority for answering an analog call.

&L0

 

 

 

 

 

 

32

20

 

POTS port 2 has higher priority for answering an analog call.

&L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S85=

 

 

bit

 

 

dec

 

hex

 

 

 

 

 

 

 

 

 

0

0

0

 

Call Bumping function disabled.

CE0

 

 

 

 

 

 

1

1 (*)

 

 

Call Bumping function enabled.

CE1

 

 

 

1-6

 

 

 

0 (*)

 

 

Add-persist time interval.

KAxn

 

 

 

7

0

0 (*)

 

 

S85b1-6 is in Second unit.

KASn

 

 

 

 

 

 

128

80

 

S85b1-6 is in Minute unit.

KAMn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S87=

 

 

bit

 

 

dec

 

hex

 

 

 

 

 

 

 

 

 

0

0 (*)

0

 

 

Enable POTS port 1 to receive global calls.

 

 

 

 

 

 

 

1

1

 

Disable POTS port 1 to receive global calls.

 

 

 

 

1

0 (*)

0

 

 

Enable POTS port 2 to receive global calls.

 

 

 

 

 

 

 

2

2

 

Disable POTS port 2 to receive global calls.

 

 

 

 

2

0 (*)

0

 

 

CHAP/PAP for authentication conversion.

 

 

 

 

 

 

 

4

4

 

PAP only for authentication conversion.

 

 

 

 

4

0 (*)

0

 

 

Result code 46 for X7 is CONNECT 112K/..

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Result code 47 for X7 is CONNECT 128K/..

 

 

 

 

 

 

 

16

10

 

Result code 46 for X7 is CONNECT 112000/..

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Result code 47 for X7 is CONNECT 128000/..

 

 

 

 

5-6

0 (*)

0

 

 

Bundle connection is disabled.

&Jn

 

B-13