Technical Reference for ZyXEL omni.net series

All the Following Commands Require a 'AT' Prefix

 

S Com.

 

 

bit

 

 

dec

 

 

hex

 

Function and description

 

 

+Def./Ref.

 

S41=

 

 

bit

 

 

dec

 

 

hex

 

Bit mapped register

+000

 

 

 

3

8

8

 

Enable CCITT signals 140 and 141 on EIA-232D interface.

 

 

 

 

 

 

5

32

20

 

DSR follows DCD and pulses (see S44b4).

 

 

&Sn

 

 

 

6

64

40

 

Force S0>=2.

 

 

S0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S42=

 

 

bit

 

 

dec

 

 

hex

 

Bit mapped register

+000

 

 

 

3

8

8

 

Disable escape sequence code in answer mode.

 

 

 

 

 

 

6

64

40

 

Disable <RINGING> result code.

 

 

Xn

 

 

 

7

128

80

 

DCD forced on, but pulse off for 0.5 seconds at carrier loss.

 

 

&C0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S44=

 

 

bit

 

 

dec

 

 

hex

 

Bit mapped register

+000

 

 

 

3

8

8

 

'ATDSn' initiates auto-dial of the stored numbers

 

 

&Zn

 

 

 

 

 

 

 

 

 

 

 

 

 

consecutively until connection is made.

 

 

S38b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

16

10

 

DSR follows DTR (see also S41b5).

 

 

&Sn

 

 

 

 

 

 

 

 

 

 

 

 

 

S50=

 

 

 

0-25

 

 

 

 

Inactivity timer for RS 232 port.

+000

 

 

 

 

 

 

5

 

 

 

 

This timer counts when there is no data flow in or out of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS 232 serial port; omni.net will hang up , when timed out.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Units is 10 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'000' disables timer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S56=

 

 

 

0-25

 

0-FF

 

Hook flash detected time for POTS port adapter, in units of

+050

 

 

 

 

 

 

5

 

 

 

 

10ms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default setting 50 = 0.5 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S57=

 

 

fax

 

 

Class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S61=

 

 

bit

 

 

dec

 

hex

 

 

 

 

 

 

 

 

3

0 (*)

0

 

MP data sent in rotate mode.

 

 

 

 

 

 

 

 

 

1

1

 

MP data sent in split mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S64=

 

 

 

 

 

dec

 

 

hex

 

 

+005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-25

 

0-FF

 

Security callback timer in unit of 1 second.

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S78=

 

 

bit

 

 

dec

 

 

hex

 

Bit mapped register

 

 

 

 

 

 

0

0 (*)

0

 

Can get busy tone from Phone 1.

 

 

 

 

B-10