Technical Reference for ZyXEL omni.net series
NOTE:
1:If you disable the call waiting function (S79.2=0 or S79.3=0), the second incoming call will be blocked.
2:If you configure the POTS port for Modem/Fax connection (S79.4=1 or S79.5=1), the call waiting feature of the respective POTS port will be always disabled.
There are several ways to deal with a second incoming call.
1.Accept the callPress the Flash key and 0 to accept the second call and put the current call on hold.
2.Reject the callPress the Flash key and 5 to reject the second incoming call.
3.Establish aPress the Flash key and 3 to establish the
The call broker function enables you to switch back and forth between the first and second calls by pressing the Flash key and 0.
When you accept a second call, you can use the call broker function to switch back and forth between caller B and C.
Step 1. Switch to caller CPress the Flash key and 0 to switch to second caller C.
Step 2. Return to caller BPress the Flash key and 0 again to switch back to caller B.